Designation Testing range by SО-1 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-1.25-40-М-003 5-50 40±2 12 1.25±0.13 16 40 х 23 х 30
P121-1.25-45-М-003 5-50 45±2 15 1.25±0.13 16 40 х 23 х 30
P121-1.25-50-М-003 5-50 50±2 15 1.25±0.13 16 40 х 23 х 30
P121-1.25-60-М-003 5-50 60±2 15 1.25±0.13 16 40 х 23 х 30

Designation Testing range by SО-1 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-1.8-40-М-003 5-50 40±2 10 1.8±0.18 16 40 х 23 х 30
P121-1.8-45-М-003 5-50 45±2 12 1.8±0.18 16 40 х 23 х 30
P121-1.8-50-М-003 5-50 50±2 12 1.8±0.18 16 40 х 23 х 30
P121-1.8-60-М-003 5-50 60±2 14 1.8±0.18 16 40 х 23 х 30

Designation Testing range by SО-1 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-2.5-40-М-003 5-50 40±2 10 2.5±0.25 16 40 х 23 х 30
P121-2.5-45-М-003 5-50 45±2 10 2.5±0.25 16 40 х 23 х 30
P121-2.5-50-М-003 5-50 50±2 12 2.5±0.25 16 40 х 23 х 30
P121-2.5-60-М-003 5-45 60±2 12 2.5±0.25 16 40 х 23 х 30
P121-2.5-65-М-003 5-45 65±2 13 2.5±0.25 16 40 х 23 х 30
P121-2.5-68-М-003 5-40 68±2 13 2.5±0.25 16 40 х 23 х 30
P121-2.5-70-М-003 5-40 70±2 14 2.5±0.25 16 40 х 23 х 30

Designation Testing range by SО-1 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-5-40-М-003 5-30 40±2 6 5±0.5 16 25 х 20 х 20
P121-5-45-М-003 5-30 45±2 6 5±0.5 16 25 х 20 х 20
P121-5-50-М-003 5-30 50±2 7 5±0.5 16 25 х 20 х 20
P121-5-60-М-003 5-20 60±2 8 5±0.5 16 25 х 20 х 20
P121-5-65-М-003 5-20 65±2 8 5±0.5 16 25 х 20 х 20
P121-5-68-М-003 5-15 68±2 8 5±0.5 16 25 х 20 х 20
P121-5-70-М-003 5-15 70±2 8 5±0.5 16 25 х 20 х 20
P121-5-73-М-003 5-15 73±2 9 5±0.5 16 25 х 20 х 20

Designation Testing range by SО-1 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-5-50-ММ-003 5-25 50±1 6 5±0.5 16 20 х 12 х 17
P121-5-65-ММ-003 5-20 65±2 6 5±0.5 16 20 х 12 х 17
P121-5-70-ММ-003 5-15 70±2 7 5±0.5 16 20 х 12 х 17
Designation Testing range by MD2-0 block Probe angle by SО-2 block X-value, up to Effective frequency Signal/noise ratio, no worse than Overall dimensions, up to
mm degr. mm MHz dB mm
P121-10-65-М-003 0.7-25* 65±2 6 10±1 16 20 х 12 х 17
P121-10-70-М-003 0.7-20* 70±2 6 10±1 16 20 х 12 х 17

• operating temperatures range is from minus 10 to plus 50 °С;

• "M"- smallsized, "MM"- miniature;

* on MD2-0-1 sample

Contact angle-beam single element surface wave transducers

Designation Effective frequency Overall dimensions, up to
MHz mm
P121-1.25-90-М-003 1.25±0.13 40 х 23 х 30
P121-1.8-90-М-003 1.8±0.18 40 х 23 х 30
P121-2.5-90-М-003 2.5±0.25 40 х 23 х 30
P121-5-90-М-003 5±0.5 25 х 20 х 20

• operating temperatures range is from minus 10 to plus 50 °С;

Ultrasonic contact angle-beam single element transducers for ultrasonic testing of small-diameter pipes

Designation Wedge angle Testing range Effective frequency Pipes diameters (хх) Pipes diameters (хх) Overall dimensions
degr. mm MHz mm dB mm
P121-5-40-dхх-003 40 9…14 5±0.5 25; 28; 30; 32; 36;
38; 42; 45; 48;50;
57; 60; 76; 83; 89;
102; 108; 114;
133; 159; 219
16 25 х 20 х 20
P121-5-51-dхх-003 51 9…12
P121-5-53-dхх-003 53 6...9
P121-5-55-dхх-003 55 3.5...6
P121-5-55-dхх-003* 58 4...6.5

* - intended for welds from austenitic steel

Special ultrasonic contact assembled transducers for pipe bends testing

Assembled transducer Transducer Wedge
Designation Resonator designation Effective frequency Element diameter Wedge angle (хх) Pipes diameters (yy)
MHz mm degr. mm
P121-2.5-хх-dyy-Р-003* P111-2.5-P12-R-003 2.5±0.25 12 30, 40 25; 28; 30; 32; 36; 38; 42; 45; 48; 50; 57; 60; 76; 83; 89; 102; 108; 114; 133; 159; 219; 273; 325; 426
P121-5-хх-dyy-Р-003* P111-5-P8-R-003 5±0.5 8

* These probes can be delivered at an extra cost.

- operating temperatures range is from minus 10 to plus 50 °С.

Special ultrasonic contact angle-beam assembled transducers

Assembled transducer Transducer
Designation Testing range by SО-1 block Probe angle by SО-2 block Resonator designation Effective frequency Element diameter
mm degr. MHz mm
P121-2.5-40-R-003* 5-50 40±2 P111-2.5-P12-R-003 2.5±0.25 12
P121-2.5-45-R-003* 5-50 45±2
P121-2.5-50-R-003* 5-50 50±2
P121-2.5-60-R-003* 5-45 60±2
P121-2.5-65-R-003* 5-45 65±2
P121-2.5-70-R-003* 5-40 70±2

* These transducers can be delivered at an extra cost.

- operating temperatures range is from minus 10 to plus 50 °С.