Print this page

Calibration Blocks for Holes Testing

 Calibration blocks for holes testing

Block name Designation  Application field
Defects parameters Roughness of operating surface, µm Overall dimensions Material Note
Length, mm Width, mm Depth, mm
KSOP2353.12 Intended for setting-up the VD3-81 Eddycon flaw detector during carrying out the holes testing using eddy current rotary scanner Aircraft, power, transportation, engineering industries. 10 0.15 0.5 Rа 0.63 150 × 50 × 10 alloy D16Т Test block is intended for testing the bolt and rivet holes or aircraft parts
0.76 0.1 0.76 Rа 0.63 ø 24 × 10 alloy D16Т